Phenylethanolamine A (PHEA) ELISA Kit

For reference only. Please follow the manual included in your kit for instructions.

Catalog Number
RDF-E015
RDF-E015
Add to Cart

For more information on our kits, please contact us at info@reddotbiotech.com

Product Description

Circle
The Phenylethanolamine A (PHEA) ELISA Kit (RDF-E015) is an enzyme-linked immunosorbent assay for quantitative detection of PHEA in Food samples with a standard range of 0.1-8.1ppb. This kit uses the Traditional ELISA format for colorimetric detection of natural PHEA in samples including Muscle,Urine,Feed. The kit is easy to use and comes with a pre-coated microplate and all necessary reagents and buffers. The standard curve generated in the experiment is used to calculate the concentration of PHEA in samples. For research use only.

Product Specifications

Circle
Product Name
Phenylethanolamine A (PHEA) ELISA Kit
Catalog Number
RDF-E015
Detection Range
0.1-8.1ppb
Species Reactivity
Food
Species
Food
Assay Length
45 minutes
Experimental Method
Competitive Inhibition
Detection Method
Colorimetric
Sample Type
Muscle,Urine,Feed
Storage
2-8°C,Avoid freeze
Shelf Life
12 monthes

Product Details

Circle

Intended Use

For the quantitative detection of phenylethanolamine A concentration in muscle, urine, and feed samples.

Assay Principle

This kit uses Competitive-ELISA as the method for the quantitative detection. It can detect Phenylethanolamine A (PHE A) in samples, such as muscle, feed. This kit is composed of ELISA Microtiter plate, HRP conjugate, antibody working solution, standard and other supplementary reagents. The microtiter plate in this kit has been pre-coated with coupled antigen. During the reaction, PHE A in the samples or standard competes with coupled antigen on the solid phase supporter for sites of anti-PHE A antibody. Then Horseradish Peroxidase (HRP) conjugate is added to each microtiter plate well, and substrate reagent is added for color development. There is a negative correlation between the OD value of samples and the concentration of PHE A. The concentration of PHE A in the samples can be calculated by comparing the OD of the samples to the standard curve.

Application Data

Circle

Reagents and Materials Provided

Reagent Quantity
ELISA Microtiter plate 96 wells
Standard Liquid 1 mL each (ppb=ng/mL=ng/g) (0 ppb, 0.1 ppb, 0.3 ppb, 0.9 ppb, 2.7 ppb, 8.1 ppb)
HRP Conjugate 5.5 mL
Antibody Working Solution 5.5 mL
Substrate Reagent A 6 mL
Substrate Reagent B 6 mL
Stop Solution 6 mL
20×Concentrated Wash Buffer 40 mL
10xReconstitution Buffer 50 mL
Plate Sealer 3
Sealed Bag 1
Manual 1
Note:

All reagent bottle caps should be tightly closed to prevent evaporation and microbial contamination.

Materials Required but not Supplied

  1. Equipment: Microplate reader, printer, homogenizer, nitrogen evaporators, vortex mixer, centrifuge, graduated pipette, Balance (sensibility 0.01 g), water bath.
  2. Micropipettes: Single channel (20-200 μL, 100-1000 μL), Multichannel (30-300 μL).
  3. Reagents: NaOH, ethyl acetate, methanol, concentrated HCl, acetonitrile, N-hexane, Na2SO4.

Storage

  1. Store the kit at 2-8℃. Do not freeze any kit components.
  2. Return any unused microwells to their original foil bag and reseal them together with the desiccant provided. Continue to store at 2-8℃.
  3. Shelf life is approximately 12 months from date of manufacture. Check packaging for expiry date.

Sample Preparation

  • Urine:
  • Take 50 μL of clear urine sample to detect (if the urine sample is turbid, it should be filtered or centrifuged at 4000 r/min for 5 min until the urine sample become clear). Temporarily used samples should be kept frozen to save.
Note: Sample dilution factor: 1, detection limit: 0.1ppb
  • Muscle:
  • Remove fat from sample, homogenize the sample with homogenizer.
  • Weigh 2±0.05 g of homogenate muscle sample, add 6mL of Acetonitrile- 0.1 M HCl Solution (Solution 3), vortex for 2 min, and centrifuge at 4000 r/min at room temperature for 10 min.
  • Take 3 mL of the supernatant, add 2 mL of 0.1 M NaOH Solution (Solution 2), add 6 mL of Ethyl acetate, vortex for 2 min, and centrifuge at 4000 r/min at room temperature for 10 min. Take all the supernatant to dry at 50-60℃with nitrogen evaporators or water bath.
  • Add 1 mL of Reconstitution Buffer (Solution 4), mix and vortex for 30s, take 50 uL liquid for analysis
Note: Sample dilution factor: 1, detection limit: 0.1ppb
  • Feed:
  • Homogenize the representative sample with a homogenizer and mix fully.
  • Weigh 1.0±0.05 g of homogenate feed sample, add 10 mL of Methanol, then add 5 g of Na2SO4, vortex for 2 min, and centrifuge at 4000 r/min at room temperature for 10min.
  • Take 1 mL of supernatant, dry at 50-60℃ with nitrogen evaporators or water bath. Dissolve the dried residual with 1 mL of Reconstitution Buffer (Solution 4), add 1 mL of N-hexane and mix for 30s. Centrifuge at 4000 r/min at room temperature for 5 min.
  • Take 50 μL of lower liquid for analysis.
Note: Sample dilution factor: 10, detection limit: 1ppb

Reagent Preparation

Solution preparation:
Prepare solutions according to the number of samples. Avoid using all components in the kit at once.
Solution 1: 0.1 M HCl Solution
Dilute 0.86 mL of Concentrated HCl to 100mL with deionized water.
Solution 2: 0.1 M NaOH Solution (for muscle sample)
Dissolve 0.4 g of NaOH to 100mL with deionized water.
Solution 3: Acetonitrile- 0.1 M HCl Solution (Solution 1)
Acetonitrile (V): 0.1 M HCl (V) =84:16 (for tissue sample)
Solution 4: Reconstitution Buffer (for muscle, feed sample)
Dilute the 10×Reconstitution Buffer with deionized water. (10×Reconstitution Buffer (V): Deionized water (V)=1:9) .The Reconstitution buffer can be store at 4℃ for a month.
Solution 5: Wash Buffer
Dilute 20×Concentrated Wash Buffer with deionized water. (20×Concentrated Wash Buffer (V): Deionized water (V) = 1:19).
Notes:
  • Bring all reagents and samples to room temperature before use.
  • Turn on the microplate reader 30 min in advance to preheat the instrument and set the testing parameters.
  • All experimental apparatus should be clean, and disposable pipette should be used and changed frequently to avoid cross-contamination during the experiment.

Assay Procedure

Restore all reagents and samples to room temperature (25℃) before use. All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. The unused ELISA Microtiter plate should be sealed as soon as possible and stored at 2~8℃.

  1. Number: number the samples and standards in order (multiple wells), and keep a record of the plate layout. Standards and Samples must be tested in duplicate.
  2. Add Sample: add 50 μL of Standard or Sample to each well, then add 50 μL of HRP Conjugate, then add 50 μL of Antibody Working Solution into each well. Oscillate gently for 5 s to mix thoroughly and cover the plate with a plate sealer, then incubate at 25℃ for 30 min in the dark.
  3. Wash: Carefully remove the plate sealer, then remove the liquid from each well. Immediately add 300 μL of Wash Buffer (Solution 5) to each well and wash. Repeat wash procedure 5 times, 30 s intervals each time. Invert the plate and pat it against a thick sheet of absorbent paper (If there are bubbles in the wells, clean pipette tips can be used to pop them).
  4. Color Development: add 50 μL of Substrate Reagent A to each well, and then add 50 μL of Substrate Reagent B. Gently oscillate for 5 s to mix thoroughly. Incubate at 25℃ for 15 min in the dark (The reaction time can be extended according to the amount of color change).
  5. Stop Reaction: add 50 μL of Stop Solution to each well. Gently oscillate to mix thoroughly.
  6. OD Measurement: determine the optical density (OD value) of each well at 450 nm (reference wavelength 630 nm) with a microplate reader. This step should be performed no later than 10 min after the reaction has been stopped.

Calculation of Results

Absorbance (%) = A/A₀×100%

  • A: Average absorbance of standard or sample
  • A₀: Average absorbance of 0 ppb Standard
  • Drawing and calculation of standard curve
  • Create a standard curve by plotting the absorbance percentage of each standard on the y-axis against the log concentration on the x-axis to draw a semi-logarithmic plot. Add the average absorbance value of each sample to the standard curve to calculate the corresponding concentration. If samples have been diluted, the concentration calculated from the standard curve must be multiplied by the dilution factor.
  • We recommend using professional software for fast and accurate analysis of large numbers of samples.

Product Data

Circle

Reaction conditions (Incubation time and temperature)

25℃; 30 min, 15 min

Detection limit

Urine---0.1 ppb, Muscle---0.1 ppb, Feed---1 ppb

Cross-reactivity

PHE A ---100%, Clenbuterol ---<1%, Salbutamol ---<1%, Ractopamine ---<1%

Sample recovery rate

Urine ---95%±15%, Muscle, Feed ---85%±15%