Circle
The beta-agonist (β-agonist) ELISA Kit (RDF-E078) is an enzyme-linked immunosorbent assay for quantitative detection of β-agonist in Food samples with a standard range of 0.2-16.2ppb. This kit uses the Traditional ELISA format for colorimetric detection of natural β-agonist in samples including Urine,Muscle,Serum. The kit is easy to use and comes with a pre-coated microplate and all necessary reagents and buffers. The standard curve generated in the experiment is used to calculate the concentration of β-agonist in samples. For research use only.

Product Specifications

Circle
Product Name
beta-agonist (β-agonist) ELISA Kit
Catalog Number
RDF-E078
Detection Range
0.2-16.2ppb
Species Reactivity
Food
Species
Food
Assay Length
45 minutes
Experimental Method
Competitive Inhibition
Detection Method
Colorimetric
Sample Type
Urine,Muscle,Serum
Storage
2-8°C,Avoid freeze
Shelf Life
12 monthes

Product Details

Circle

Intended Use

For the quantitative detection of ß-agonist concentration in urine, muscle, and serum samples.

Assay Principle

This kit uses Competitive-ELISA as the method for the quantitative detection. It can detect β-agonist in samples, such as muscle, urine, etc. This kit is composed of ELISA Microtiter plate, HRP conjugate, antibody working solution, standard and other supplementary reagents. The microtiter plate provided in this kit has been pre-coated with coupled antigen. During the detection, β-agonist in the samples or standard competes with coupled antigen on the solid phase supporter for sites of anti- β-agonist antibody. Then Horseradish Peroxidase (HRP) conjugate is added to each well, and substrate reagent is added for color development. There is a negative correlation between the OD value of samples and the concentration of β-agonist. The concentration of β-agonist in the samples can be calculated by comparing the OD of the samples to the standard curve.

Application Data

Circle

Reagents and Materials Provided

Reagent Quantity
ELISA Microtiter plate 96 wells
Standard Liquid 1 mL each (ppb=ng/mL=ng/g) (0 ppb, 0.2 ppb, 0.6 ppb, 1.8 ppb, 5.4 ppb, 16.2 ppb)
HRP Conjugate 12 mL
Antibody Working Solution 7 mL
Sample Stabilizer 5 mL
Sample Diluent 30 mL
Substrate Reagent A 6 mL
Substrate Reagent B 6 mL
Stop Solution 6 mL
20xConcentrated Wash Buffer 25 mL
Plate Sealer 3
Sealed Bag 1
Manual 1
Note:

All reagent bottle caps should be tightly closed to prevent evaporation and microbial contamination.

Materials Required but not Supplied

  1. Equipment: Microplate reader, printer, homogenizer, vortex mixer, centrifuge, balance (sensibility 0.01 g).
  2. Micropipettes: Single channel (20-200 μL, 100-1000 μL), Multichannel (30-300 μL).
  3. Reagents: Methanol.

Storage

  1. Store the kit at 2-8℃. Do not freeze any kit components.
  2. Return any unused microwells to their original foil bag and reseal them together with the desiccant provided. Continue to store at 2-8℃.
  3. Shelf life is approximately 12 months from date of manufacture. Check packaging for expiry date.

Sample Preparation

  • Urine (swine):
  • Take 50 μL of fresh urine to detect directly (Filtrate or centrifuge for 5 min at 4000 rpm if the urine sample is turbid).
Note: Sample dilution factor: 1, detection limit: 1 ppb
  • Urine (cattle, sheep):
  • Take 1 mL of fresh urine into centrifuge tube (Filtrate or centrifuge for 5 min at 4000 rpm if the urine sample is turbid).
  • Add 40 μL of Sample Stabilizer, oscillate for 5 min.
  • Take 50 μL for detection.
Note: Sample dilution factor: 1, detection limit: 1 ppb
  • Muscle (pork, mutton, beef):
  • Remove fat from sample, homogenize the sample with homogenizer.
  • Weigh 2±0.05 g of homogenate fresh sample into a 50 mL centrifuge tube;
  • Add 4 mL of 1% Trichloroacetic acid (Solution 1), oscillate for 5 min.
  • Centrifuge for 5 min at 4000 rpm;
  • Take 1 mL of intermediate layer solution into a new centrifuge tube;
Note: Avoid taking the upper or lower solids.
  • Add 30 μL of 1 M NaOH Solution (Solution 2) and oscillate for 10s thoroughly;
  • Centrifuge for 5 min at 4000 rpm;
  • Take 50 μL of supernatant for detection immediately.
Note: Sample dilution factor: 3, detection limit: 1 ppb
  • Serum (swine, cattle, sheep):
  • Take 200 μL of serum into a 2 mL centrifuge tube;
Note: Avoid hemolysis while taking blood. Take the supernatant for detection after Centrifuge if the serum is cloudy.
  • Add 200 μL of Sample Diluent and oscillate for 30 s;
  • Put the sample into water bath at 80℃ to incubate for 5 min;
  • Restore samples to room temperature, and take 50 μL for detection.
Note: Sample dilution factor: 2, detection limit: 1 ppb

Reagent Preparation

Solution preparation:
Prepare solutions according to the number of samples. Avoid using all components in the kit at once.
Solution 1: 1% Trichloroacetic acid (for pork, mutton, beef sample)
Dilute 10 g of Trichloroacetic acid to 1000 mL with deionized water, mix fully.
Solution 2: 1 M NaOH Solution (for pork, mutton, beef sample)
Dilute 4 g of NaOH to 100 mL with deionized water, mix fully.
Solution 3: Wash Buffer
Dilute 20×Concentrated Wash Buffer with deionized water. (20×Concentrated Wash Buffer (V): Deionized water (V) = 1:19).
Notes:
  • Bring all reagents and samples to room temperature before use.
  • Turn on the microplate reader 30 min in advance to preheat the instrument and set the testing parameters.
  • All experimental apparatus should be clean, and disposable pipette should be used and changed frequently to avoid cross-contamination during the experiment.

Assay Procedure

Bring all reagents and samples to room temperature (25℃) before use. All reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Any unused Microtiter plate wells should be resealed as soon as possible and stored at 2-8℃.

  1. Number: number the samples and standards in order (multiple wells), and keep a record of the plate layout. Standards and Samples must be tested in duplicate.
  2. Add Sample: add 50 μL of Standard or Sample to each well, then add 50 μL Antibody Working Solution, and cover the plate with plate sealer. Oscillate gently for 10 s to mix thoroughly, then incubate at 25℃ for 15 min in the dark.
  3. Wash: Carefully remove the plate sealer, then remove the liquid from each well. Immediately add 260 μL of Wash Buffer (Solution 3) to each well and wash. Repeat wash procedure 4 times, 30 s intervals each time. Invert the plate and pat it against a thick sheet of absorbent paper (If there are bubbles in the wells, clean pipette tips can be used to pop them).
  4. HRP Conjugate: add 100 μL of HRP Conjugate to each well, incubate at 25℃ for 15 min in the dark.
  5. Wash: repeat step 3.
  6. Color Development: add 50 μL of Substrate Reagent A to each well, and then add 50 μL of Substrate Reagent B. Gently oscillate for 10 s to mix thoroughly. Incubate at 25℃ for 15 min in the dark (The reaction time can be extended according to the amount of color change).
  7. Stop Reaction: add 50 μL of Stop Solution to each well. Gently oscillate for 10 s to mix thoroughly.
  8. OD Measurement: determine the optical density (OD value) of each well at 450 nm (reference wavelength 630 nm) with a microplate reader. This step should be performed no later than 5 min after the reaction has been stopped.

Calculation of Results

Absorbance (%) = A/A₀×100%

  • A: Average absorbance of standard or sample
  • A₀: Average absorbance of 0 ppb Standard
  • Drawing and calculation of standard curve
  • Create a standard curve by plotting the absorbance percentage of each standard on the y-axis against the log concentration on the x-axis to draw a semi-logarithmic plot. Add the average absorbance value of each sample to the standard curve to calculate the corresponding concentration. If samples have been diluted, the concentration calculated from the standard curve must be multiplied by the dilution factor.
  • We recommend using professional software for fast and accurate analysis of large numbers of samples.

Product Data

Circle

Reaction conditions (Incubation time and temperature)

25℃, 15 min, 15 min, 15 min

Detection limit

Urine, Muscle, Serum --- 1 ppb

Cross-reactivity

Sample recovery rate

90%±30%.